calcPageSize())"
/>
SICK C4P-EA03011D00 1220109
In stock
Backorder allowed
Out of stock
Description / SICK C4P-EA03011D00 1220109
SICK deTec4 Core Safety Light Curtain Receiver
Description
This is the C4P-EA03011D00 receiver unit from SICK's renowned deTec4 Core series of safety light curtains. It is engineered to provide top-tier machine safety in accordance with Type 4 (IEC 61496) and PL e (EN ISO 13849) standards. With a protective field height of 300 mm and a 30 mm resolution, this receiver is ideal for applications requiring hand and finger protection. Its robust design and straightforward integration make it a dependable choice for safeguarding hazardous points and access areas in industrial environments.
Specifications
- Manufacturer: SICK
- Product Series: deTec4 Core
- Model: C4P-EA03011D00
- Part Number: 1220109
- Function: Receiver
- Resolution: 30 mm
- Protective Field Height: 300 mm
- Maximum Scanning Range: 30 m
- Supply Voltage: 24 V DC
- Safety Type: Type 4 (IEC 61496-1)
- Performance Level: PL e (EN ISO 13849)
Label Info
- Model: C4P-EA03011D00
- Part No.: 1220109
Application
This safety light curtain receiver is designed for use in a variety of industrial automation settings, including packaging machinery, assembly lines, robotics cells, and material handling systems, where reliable personnel protection is critical.
Country of Origin
Made in Germany.
CO2 Impact
Opting for this component helps avoid the CO2 emissions associated with new manufacturing, contributing to a more sustainable industrial operation. This single item saves an estimated 20.0 kg of CO2.
Availability
This item is in stock and ready for immediate dispatch. Order now from PLC2Day for expert support and fast delivery.
FAQ
Is this deTec4 receiver compatible with a sender from an older SICK series like the C4000?No, the deTec4 series uses a different communication protocol and technology. For reliable Type 4 safety operation, this receiver must be paired with a corresponding deTec4 sender.
What is the maximum cable length between the sender and receiver for the deTec4 series?The maximum cable length depends on the cable cross-section. For a standard 0.34 mm^2 cable, SICK specifies a maximum length of 50 meters to ensure signal integrity and reliable operation.
Can this C4P-EA03011D00 receiver be configured for muting or blanking functions?The 'C4P' in the model name indicates it is a deTec4 Core model. The Core series provides fundamental safety functions but does not support advanced features like muting or blanking. For those capabilities, you would need a deTec4 Prime model (C4E).
PLC2DAY is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners.
Current Date: Friday, March 13, 2026
More Information
| Item Number | C4P-EA03011D00 1220109 |
|---|---|
| Brands | SICK |
| HS Code | 90314990 |
| EAN | 0 |
| HS Description | Optical Safety Device |
| Manufacturer | Sick |
| Product Condition | Factory New |
| Packing Condition | Original Packing Packing |