Description / SCHNEIDER ELECTRIC iC60H C32A A9F84232
Schneider Electric iC60H C32A with Vigi iC60 RCD
Description
This product is a combined assembly of a Schneider Electric Acti9 iC60H miniature circuit breaker (MCB) and a Vigi iC60 add-on residual current device (RCD). It offers a complete solution for circuit protection in commercial and industrial environments, providing safety against overloads, short circuits, and earth leakage currents. The C-curve characteristic is suitable for circuits with moderate inrush currents, while the 30mA sensitivity ensures protection for personnel.
Specifications
- Manufacturer: Schneider Electric
- Series: Acti9
- MCB Model: iC60H
- RCD Module: Vigi iC60
- Rated Current: 32A
- Poles: 2-Pole
- Tripping Curve: C
- Residual Current Sensitivity: 30mA
- RCD Type: A
- Rated Voltage: 230-400V AC 50/60Hz
Label Info
- Standard (MCB): IEC/EN 60898-1, IEC/EN 60947-2
- Breaking Capacity (Icn) at 400V: 6000A
- Breaking Capacity (Icu) at 415V: 50kA
- Impulse Withstand Voltage (Uimp): 6kV
- Insulation Voltage (Ui): 500V
Application
This device is ideal for final distribution boards in industrial and commercial buildings. It is used to protect circuits for lighting, standard outlets, and small motors, where both overcurrent and earth fault protection are required in a compact form factor.
Country of Origin
Made in France.
CO2 Impact
By purchasing this pre-owned component, you are helping to avoid approximately 17 kg of CO2 emissions. This is equivalent to the savings from driving a standard car for 85 kilometers.
Availability
This item is in stock and ready for immediate dispatch. Order now from PLC2Day for expert support and fast delivery.
FAQ
What is the difference between a Type A and Type AC RCD?
A Type AC RCD is designed to detect sinusoidal AC fault currents. A Type A RCD, like this Vigi iC60, detects both sinusoidal AC and pulsating DC fault currents, which can be generated by electronic equipment like variable speed drives or IT equipment. This makes Type A suitable for a wider range of modern applications.
Can the Vigi iC60 RCD block be separated from the iC60H MCB?Yes, the Vigi iC60 is a modular add-on block. It can be detached from the iC60H circuit breaker and replaced or used with another compatible Acti9 MCB, provided the current rating of the MCB does not exceed the Vigi module's rating (in this case, up to 63A).
What does the 'H' in iC60H signify?The 'H' in the iC60H model name indicates a higher breaking capacity compared to the standard iC60N model. The iC60H typically has a breaking capacity of 10kA according to IEC/EN 60898-1, making it suitable for applications in commercial and industrial environments where higher short-circuit currents can occur.
Last Update: Friday, March 13, 2026
PLC2DAY is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners.
More Information
| Item Number | iC60H C32A A9F84232 |
|---|---|
| Brands | Schneider Electric |
| HS Code | 85362010 |
| EAN | 3606480080371 |
| HS Description | Miniature Circuit Breaker |
| Manufacturer | SCHNEIDER ELECTRIC |