Article number: 2607071050

In stock

Backorder allowed

Out of stock

This used Eaton Vickers DG5V-7 hydraulic directional valve offers reliable performance for high-flow industrial applications. A robust CETOP 7 valve, it's the perfect spare part to get your system running again. Order today from PLC2Day.

Description / EATON VICKERS DG5V-7-6C-M-U-C6-40

Eaton Vickers Two-Stage Hydraulic Directional Valve

Description

This is a used DG5V-7-6C-M-U-C6-40 two-stage directional control valve from Eaton Vickers. It is a high-performance, solenoid-operated valve designed for industrial hydraulic systems. This assembly features a DG4V-3S pilot valve on a DG5V-7 main stage, providing precise control of high flow rates. The unit is in used condition and is supplied without solenoid coils.

Specifications

  • Manufacturer: Eaton Vickers
  • Main Stage Model: DG5V-7-6C-M-U-C6-40
  • Pilot Valve Model: DG4V-3S-6C-M-U-CG-60
  • Valve Size: CETOP 7 / NG16 / NFPA D07
  • Spool Type: 6C - Spring Centered, Closed Center
  • Mounting Interface: ISO 4401-07
  • Condition: Used, coils not included

Application

Ideal for applications in machine tools, presses, metalworking machinery, and other industrial equipment requiring reliable and high-capacity hydraulic fluid directional control.

Country of Origin

Manufactured in Germany.

CO2 Impact

Choosing this reused valve over a new one prevents the emission of approximately 24 kg of CO2, contributing to a more sustainable industrial practice.

Availability

This item is in stock and ready for immediate dispatch. Order now from PLC2Day for expert support and fast delivery.

FAQ

What is the significance of the "6C" spool type in this DG5V-7 valve?

The "6C" code specifies a spring-centered, closed-center spool. In the neutral position, all ports (P, T, A, B) are blocked, which holds the actuator in a fixed position and prevents fluid from flowing through the valve. This is common in applications requiring load-holding capabilities when the valve is de-energized.

This valve is missing its solenoid coils. Can I use any coils?

No, you must use coils that match the specifications of the pilot valve, a DG4V-3S. The model code specifies 'U' for Universal Plug-in coils and originally had a 'CG' type (24V DC). You must use a compatible Eaton Vickers coil for the DG4V-3 series valve body to ensure proper fit, sealing, and electrical performance.

What does the CETOP 7 / NG16 size designation mean for installation?

CETOP 7 (also known as NG16 or NFPA D07) refers to the standardized mounting interface for the valve. This means the bolt pattern, port locations, and dimensions of the mounting surface are standardized, allowing interchangeability with other valves that conform to the CETOP 7 standard, regardless of the manufacturer.

PLC2DAY is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.

Last Update: Friday, March 13, 2026

More Information

Item Number DG5V-7-6C-M-U-C6-40
Brands Eaton Vickers
HS Code 848120
EAN 0
HS Description Oleohydraulic transmission valves
Manufacturer Eaton Vickers
Product Condition Used
Packing Condition Neutral Packing Packing

Review Form

Write Your Own Review
You're reviewing: EATON VICKERS DG5V-7-6C-M-U-C6-40
Your Rating:
loader
Loading...

check-circle You submitted your review for moderation.

This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.